Product Specifications


Thermal Performance - ASTM C158
( R-Value)  
R 3.6 per Inch
  Avg. 2"x4" = R 13 Avg. 2"x6" = R 20
Because Icynene is a spray in place foam it is always custom fit, so it will maintain a consistent, absolute R-Value for the life of the product.
Air Permeance - ASTME 283
0.0049 l/s-m2 @
75 Pa for 5.25" 0.0080 l/s-m2 @ 75 Pa for 3.25"
This means you require No Additional Interior/Exterior infiltration protection.
Vapor Permeance - ASTM E96
16 Perms 941 n/g @ 3" 10 Perms 565 n/g @ 5"Icynene is Hydrophobic meaning it will not absorb water, however water will drain by gravity.
Upon drying, will return to its full thermal capabilities.
Flame Spread - ASTM E84

Flame Spread <20

Smoke Development- ASTM E84

Flame Spread <400

Fuel Contribution- ASTM E84

Zero
 